Received- July 29, 2016; Accepted- November 15, 2016
 International Journal of Biomedical Science 12(4), 130-142, Dec 15, 2016
ORIGINAL ARTICLE


© 2016   Hilal S. Mohammed et al. Master Publishing Group

Evaluate the Effect of Commercially Available Denture Cleansers on Surface Hardness and Roughness of Denture Liners at Various Time Intervals

Hilal S. Mohammed1, Sumeet Singh2, Prasad A. Hari3, G. S. Amarnath4, Vinaya Kundapur5, Naveed Pasha6, M. Anand7

1 Reader, Department of prosthodontics, M R Ambedkar Demtal college & Hospital, Bangalore, INDIA;

2 Post graduate student, Department of prosthodontics, M R Ambedkar Demtal college & Hospital, Bangalore, INDIA;

3 Reader, Department of prosthodontics, M R Ambedkar Dental College & Hospital, Bangalore, INDIA;

4 Professor & HOD, Department of Prosthodontics, M R Ambedkar Dental College & Hospital, Bangalore, INDIA;

5 Senior Lecturer, Departemenrt of prosthodontics, M R Ambedkar Dental College & Hospital, Bangalore, INDIA;

6 Post graduate student, Department of prosthodontics, M R Ambedkar Demtal college & Hospital, Bangalore, INDIA;

7 Reader, department of prosthodontics, M R Ambedkar Dental College & Hospital, Bangalore, INDIA

Corresponding Author: Vinaya Kundapur, 5Senior Lecturer, Departemenrt of prosthodontics, M R Ambedkar Dental College & Hospital, Bangalore, INDIA. E-mail: drvinni@gmail.com.


  ABSTRACT
INTRODUCTION
MATERIALS & METHODS
RESULTS
DISCUSSION
CONCLUSION
REFERENCES


 ABSTRACT

Background and objective: Chemical cleansing by denture cleansers is first choice for denture plaque control. The most common problems while using denture cleansers are hardening, porosity, odor sorption, water sorption, solubility, and colour change, bacterial and fungal growth. Chemical cleansing procedures have been found to have an effect on the physical and mechanical properties of denture liners. Thus, this study was conducted to evaluate the effect of commercially available denture cleansers on surface hardness and roughness of acrylic and silicon based denture liners at various time interval. Method: Two autopolymerising denture liners Kooliner (acrylic) and GC reline soft (silicon) were tested with two commercially available denture cleansers, polident and efferdent plus. Total of 120 specimens were prepared and all the specimens were divided into six groups based on the relining materials and denture cleansers used. Surface hardness and surface roughness was tested using Shore A durometer and profilometer respectively at the end of day 1, day 7, day 30 and day 90. All the specimens were stored in artificial saliva throughout the study. Cleanser solution was prepared daily by adding Polident and Efferdent plus denture cleanser tablet into 250ml of enough very warm (not hot) water. Acrylic and silicon liner groups were cleansed in a solution of denture cleanser and water for 15 minutes daily, rinsed with water and stored in artificial saliva at room temperature. The data was analyzed with one way ANOVA and independent t-test. Result: The acrylic soft lining showed gradual hardening and increase in surface roughness after immersion in denture cleanser and also with time. Acrylic liner material showed maximum hardness and roughness with Polident followed by Efferdent plus and water (control group). Silicone lining material showed a slight difference in hardness and roughness between the test group and control group. There was a slight increase in hardness in all the groups with time. Very slight increase in mean surface roughness of all the silicon liner groups from day 1 to day 90 was observed. A statistically significant change was noted between and within the all silicon liner groups on day 7, day 30 and day 90. Conclusion: The average surface hardness and surface roughness were lower in silicon liner material than acrylic liner material. Maximum surface roughness was noted by Polident followed by Efferdent Plus and Water for both acrylic liner group and silicon liner group.

KEY WORDS:    Acrylic liner, Silicon liner, Denture cleanser, Surface hardness, Surface roughness

 INTRODUCTION

   The accuracy of denture fit is an important factor in the retention of denture. The use of resilient lining materials are useful in removable prosthodontics because of their capability of restoring health to inflamed mucosa, leading to more equal distribution of functional load on the denture foundation area and improving the fitting denture surface and retention of the prosthesis (1). Soft denture lining materials have been used in dentistry for more than a century, with earliest soft liner being natural rubbers. One of the first synthetic resins developed in 1945 as a soft liner was a plasticized poly vinyl resin followed by the introduction of silicones in 1958 (2).

   The resilient denture lining materials can be divided into two types: plasticized acrylic resins and silicone elastomers. Acrylic resin-based resilient denture liners often contain plasticizers that may leach out of the material, resulting in hardening of the liners with time. For silicone-based resilient lining materials, the polymer is an elastomer, which does not require an external plasticizer and is therefore, more stable over time. Resilient reline materials are available in autopolymerizing and heat polymerizing forms. Autopolymerizing relining materials can be an attractive alternative to heat-polymerized liners because they can be placed chairside, are easier to apply, and require no laboratory procedures (3). Rigid auto-polymerizing acrylic resin is used to reline dentures directly in the mouth. The resin is polymerized by mixing a powder of poly (methyl methacrylate) with aliquid of methyl methacrylate and using peroxides, amines, and plasticizers to control the chemical process. The effect of this chemical reaction on the oral mucosa are unknown; however, many patients find the procedure uncomfortable and distasteful (4). The use soft denture liners has become increasingly popular for providing comfort for denture wearers. Soft denture liners are often used for patients who cannot tolerate a conventional denture base (5).

   Success of dentures made from two different materials depends on adequate bond between the materials. Hence, reason for failure of soft lined denture is structural differences between the materials. Hardness of denture liners is most important, with a direct impact on malleability, ductibility and abrasion resistance. Surface roughness is also important property of a denture liner, as rough denture surface leads to biofilm formation and colonization by Candida albicans (6). Routine dentures cleaning not only removes plaque and prevent re-accumulation plaque, it also removes mucin, calculus, food debris, calculus, and exogenous discoloration (7).

   Denture plaque control using mechanical and chemical methods is essential for maintenance of good oral hygiene of denture wearers. However, mechanical cleansing is not advisable for soft denture liners since it can damage resilient lining. Chemical cleansing by denture cleansers is first choice for denture plaque control (8). The most common problems while using denture cleansers are hardening, porosity, odor sorption, water sorption, solubility, and colour change, bacterial and fungal growth (9).

   Although chemical cleansing has been considered an efficacious method to prevent Candida albicans invasion and denture plaque formation, some types of denture cleansers have been reported to cause significant deterioration of tissue conditioners in a relatively short time. A roughened surface facilitates colonization by microorganisms. Therefore denture cleansers used for plaque control of tissue conditioners should reduce microbial contamination and have a minimum effect on physical properties of liner (10).

   The most common problems encountered while using soft denture liners are water sorption and solubility. In use, they are constantly bathed in saliva, and when out of the mouth, they are usually immersed either solution or denture cleansers or water for storage. During such immersion, soft lining materials undergo two responses: plasticizers and other soluble components are leached out and water or saliva is absorbed. So, an ideal processed soft liner should have no soluble components and low water sorption (11).

   As per the data acquired through studies conducted, hygiene procedures have been found to have an effect on the physical and mechanical properties of denture liners because they can cause loss of plasticizers and soluble component, or water absorption or absorption of saliva by the denture lining materials. Thus, the aim of this study is to evaluate the effect of commercially available denture cleansers on surface hardness and surface roughness of various denture liners.

   The aim and objective of this study was:

   1) To determine the influence of denture cleansers on surface hardness and surface roughness of denture liners.

   2) To compare the efficiency of commercially available denture cleansers on denture liners.

 MATERIALS & METHODS

   A total of hundred and twenty cylindrical specimens were made using custom made metal mould with the dimension of 15 mm in diameter and 10 mm in height (according to ASTM: D -2240 64T).

   Preparation of kooliner specimens

   Total sixty kooliner specimens were made of dimension of 15 mm × 10 mm with the help of custom made metal mould. Petroleum jelly was applied on the mould for easy removal of the specimens. Base of the mould was placed on a glass slab covered with cellophane sheet to facilitate separation of mould from the glass slab. Both the relining materials were manipulated according to manufacturer instructions. Recommended power/liquid ratio for kooliner is 15 ml powder to 6ml liquid. Pour liquid into the mixing cup and then add the powder slowly. Stir thoroughly for no more than 30 seconds and avoid the introduction of air bubble. After approximately 1-2 minutes expressed the mix into the mould. The mould was then covered with cellophane sheet and another glass slab was pressed tightly against the mould to remove the excess material and to shape the specimens according to the dimensions of the mould. When curing was complete (10 minutes), specimens were removed from the mould and excess was trimmed.

   Preparation of GC reline soft specimens

   Total sixty GC reline soft specimens were made of dimension of 15 × 10 mm with the help of custom made metal mould. Petroleum jelly was applied on the mould for easy removal of the specimens. Base of the mould was placed on a glass slab covered with cellophane sheet to facilitate separation of mould from glass slab. GC reline soft cartridge was attached to the cartridge dispenser, cartridge cap was replaced with mixing tip and material was directly expressed into the metal mould.

   The mould was then covered with cellophane sheet and another glass slab was pressed tightly against the mould to remove the excess material and to shape the specimens according to the dimensions of the mould. After setting time of 4 minutes of the material, specimens were removed from the mould and using a B.P. blade, excess material on the edge was removed. Cleanser solution was prepared daily by adding Polident or Efferdent plus denture cleanser tablet into 250ml of enough very warm (not hot) water.

   Storage and cleansing of specimens

   All the specimens were divided into six groups based on the relining materials and denture cleansers used and each group was tested at a time interval of day 1, day 7, day 30 and day 90. All the specimens were stored in artificial saliva throughout the study. Specimens of group AP (Acrylic specimen cleansed daily in Polident denture cleanser) and SP(Silicon specimen cleansed daily in Polident denture cleanser) were cleansed in a solution of Polident denture cleanser solution for 15 minutes daily, rinsed in water and stored in artificial saliva at room temperature. Specimens of group AE (Acrylic specimen cleansed daily in Efferdent plus denture cleanser) and SE (Silicon specimen cleansed daily in Efferdent denture cleanser) were cleansed daily in a solution of Efferdent denture cleanser solution for 15 minutes, rinsed in water and stored in artificial saliva at room temperature. Specimens of group AW (Acrylic specimen cleansed daily in Water) and SW (Silicon specimen cleansed daily in Water) were cleansed daily on water and stored in artificial saliva at room temperature.

   Total of 120 specimens were prepared and divided into 6 groups

   Kooliner specimen cleansed daily in Polident denture cleanser-20;

   Kooliner specimen cleansed daily in Efferdent denture cleanser-20;

   Kooliner specimen cleansed daily in water-20;

   GC reline soft specimen cleansed daily in Polident denture cleanser-20;

   GC reline soft specimen cleansed daily in Efferdent denture cleanser-20;

   GC reline soft specimen cleansed daily in water -20.

   Testing of specimens

   Specimens were subjected to surface hardness and surface roughness testing at time intervals of day 1, day 7, day 30 and day 90. Hardness was measured using Shore A durometer and surface roughness was measured using Profilometer.

   Statistical Methods Employed

   Mean, Standard deviation, Independent sample t-test and ANOVA were the statistical methods employed in the study. ANOVA was performed across mean of the specimen group for each series of test when significant statistical difference was detected. Independent sample t-test at the significance level of 0.05 was applied to the groups to determine statistical difference between two means.

 RESULTS

   Statistical analysis, as given in Table 1, showed that on day 1 both the test (AP and AE) and control (AW)acrylic liner groups showed no difference in hardness but there was significant (P<0.05) increase in hardness was noted between and within the all acrylic liner groups on day 7, day 30 and day 90. The highest mean hardness was observed in AP acrylic liner group followed by AE and AW acrylic liner group (Graph 1).

   Table 2 shows that there was an increase in mean surface roughness (Ra) from day 1 to day 90 of both test (AP and AE) and control (AW) acrylic liner groups but a statistically significant (P<0.05) increase in surface roughness was noted between and within the all acrylic liner on day 7, day 30 and day 90. Highest mean surface roughness was observed in AP acrylic liner group followed by AE and AW acrylic liner group (Graph 2).

   Table 3 shows that there was a slight increase in hardness of all the silicon liner groups (SP, SE and SW) from day 1 to day 90 but a statistically significant (P<0.05) change was noted between and within the all silicon liner groups (SP, SE and SW) on day 7, day 30 and day 90. The highest mean hardness was observed in SP silicon liner group followed by SE and SW silicon liner group (Graph 3).

   Table 4 shows that there was very slight increase in mean surface roughness (Ra) of all the silicon liner groups from day 1 to day 90 and no significant (P>0.05) change in surface roughness was noted between and within the groups of the test (SP and SE) and control (AW) silicon liner groups on day 1 but a statistically significant (P<0.05) change was noted between and within the all silicon liner groups (SP, SE and SW) on day 7, day 30 and day 90. The highest mean roughness was observed in SP silicon liner group followed by SE and SW silicon liner group (Graph 4).

   Table 5 shows that Acrylic liner group (AP) showed higher surface hardness than silicon liner group (SP) when treated with cleanser P. This difference was statistically significant at all time intervals (Graph 5).

   Table 6 shows that Acrylic liner group (AE) showed higher surface hardness than silicon liner group (SE) when treated with cleanser E. This difference was statistically significant at all time intervals (Graph 6).

   Table 7 shows that Acrylic liner group (AW) showed higher surface hardness than silicon liner group (AW) when treated with cleanser W. This difference was statistically significant at all time intervals (Graph 7).

   Table 8 shows that Acrylic liner group (AP) showed higher surface roughness than silicon liner group (SP) when treated with cleanser P. This difference was statistically significant at all time intervals (Graph 8).

   Table 9 shows that Acrylic liner group (AE) showed higher surface roughness than silicon liner group (SE) when treated with cleanser E. This difference was statistically significant at all time intervals (Graph 9).

   Table 10 shows that Acrylic liner group (AW) showed higher surface roughness than silicon liner group (SW) when treated with cleanser W. This difference was statistically significant at all time intervals (Graph 10).

View this table:
[in a new window]
Table 1. One way analysis of variance for mean surface hardness of acrylic liner groups


View this table:
[in a new window]
Table 2. One way analysis of variance for mean surface roughness of acrylic liner groups


View this table:
[in a new window]
Table 3. One way analysis of variance for mean surface hardness of silicon liner groups


View this table:
[in a new window]
Table 4. One way analysis of variance for mean surface roughness of silicon liner groups


View this table:
[in a new window]
Table 5. Comparison of mean surface hardness between acrylic and silicon liner groups when treated with cleanser P at all time interval (AP, SP)


View this table:
[in a new window]
Table 6. Comparison of mean surface hardness between acrylic and silicon liner groups when treated with cleanser E at all time interval (AE, SE)


View this table:
[in a new window]
Table 7. Comparison of mean surface hardness between acrylic and silicon liner groups when treated with cleanser W at all time interval (AW, SW)


View this table:
[in a new window]
Table 8. Comparison of mean surface roughness between acrylic and silicon liner groups when treated with cleanser P at all time interval (AP, SP)


View this table:
[in a new window]
Table 9. Comparison of mean surface roughness between acrylic and silicon liner groups when treated with cleanser E at all time interval (AE, SE)


View this table:
[in a new window]
Table 10. Comparison of mean surface roughness between acrylic and silicon liner groups when treated with cleanser W at all time interval (AW, SW)

 DISCUSSION

   The accuracy of denture fit is an important factor in the retention of denture. However, the process of alveolar resorption is irreversible and may lead to inadequate fit of prosthesis. The use of resilient lining materials is useful in removable prosthodontics because of their capability of restoring health of inflamed mucosa (1).

   Liners are made-up of materials from several chemical families. These materials undergo chemical changes over time as patients use dentures in either the aqueous environment of their mouth or, if not in use, then in tap water or denture cleansers. The most common problems while using denture cleansers are hardening, porosity, odor sorption, water sorption, solubility, and color change, bacterial and fungal growth.6 Hardness of denture liner is important, with a direct impact on malleability, ductibility and abrasion resistance. Surface roughness is also important property of a denture liner, as rough denture surface leads to biofilm formation and colonization of Candida albicans (7).

   Denture plaque control using mechanical and chemical methods is essential for maintenance of good oral hygiene of denture wearers. However, mechanical cleansing is not advisable for soft denture liners since it can damage resilient lining. Chemical cleansing by denture cleansers is first choice for denture plaque control. The solutions used for denture cleansing can be divided according to their chemical composition: alkaline peroxide, alkaline hypochlorite, acids, disinfectants and enzymes. Peroxide cleansers are the most commonly used denture cleansers. They are dispensed in powder or tablet forms, which become alkaline solutions of hydrogen peroxide when dissolved in water (9).

   Although chemical cleansing has been considered an efficacious method to prevent Candida albicans invasion and denture plaque formation, some types of denture cleansers have been reported to cause significant deterioration of tissue conditioners in a relatively short time. A roughened surface facilitates colonization by microorganisms. Therefore denture cleansers used for plaque control of tissue conditioners should reduce microbial contamination and have a minimum effect on physical properties of liner (10).

   The most common problems encountered while using soft denture liners are water sorption and solubility. In use, they are constantly bathed in saliva, and when out of the mouth, they are usually immersed either solution or denture cleansers or water for storage. During such immersion, soft lining materials undergo two responses: plasticizers and other soluble components are leached out and water or saliva is absorbed. So, an ideal processed soft liner should have no soluble components and low water sorption (11).

   Total hundred and twenty specimens were made of dimension of 15 × 10 mm (according to ASTM: D -2240-64T). All the specimens were divided into six groups based on the relining materials and denture cleansers used and each group was tested at a time interval of day 1, day 7, day 30 and day 90. All the specimens were stored in artificial saliva throughout the study. Statistical analysis, showed that on day 1 both the test (AP and AE) and control (AW)acrylic liner groups showed no difference in hardness but there was significant (P<0.05) increase in hardness was noted between and within the all acrylic liner groups on day 7, day 30 and day 90. The highest mean hardness was observed in AP acrylic liner group followed by AE and AW acrylic liner group. Slight increase in hardness of all the silicon liner groups (SP, SE and SW) from day 1 to day 90 but a statistically significant (P<0.05) change was noted between and within the all silicon liner groups(SP, SE and SW) on day 7, day 30 and day 90. The highest mean hardness was observed in SP silicon liner group followed by SE and SW silicon liner group. There was an increase in mean surface roughness (Ra) from day 1 to day 90 of both test (AP and AE) and control (AW) acrylic liner groups but a statistically significant (P<0.05) increase in surface roughness was noted between and within the all acrylic liner on day 7, day 30 and day 90. Highest mean surface roughness was observed in AP acrylic liner group followed by AE and AW acrylic liner group. Very slight increase in mean surface roughness (Ra) of all the silicon liner groups from day 1 to day 90 and no significant (P>0.05) change in surface roughness was noted between and within the groups of the test (SP and SE) and control (AW) silicon liner groups on day 1.

   Acrylic liner group showed higher surface hardness than silicon liner group when treated with cleanser P, cleanser E and cleanser W. These differences were statistically significant at all time intervals. Acrylic liner group showed higher surface roughness than silicon liner group when treated with cleanser P, cleanser E and cleanser W. These differences were statistically significant at all time intervals. Malherios-Segundo et al verified in their study that there was significant increase in hardness throughout their study in both groups (Control group-immersion in artificial saliva at 37°C and Experimental group – immersion in artificial saliva at 37 C combined with immersion in the cleanser for 5 min) for both the materials (Rigid liner–Kooliner and Soft liner- Elite soft). No significant alteration in surface roughness was caused by immersion in sodium perborate when compared to immersion in artificial saliva for the same time (7).

   In our study, there is a significant increase in hardness and surface roughness in all the groups for both the material. However, there were more significant changes hardness in the acrylic liner group than silicone liner group. Hence, the above mentioned study is in favour of our study. Pahuja et al conducted a study which showed that silicone based soft denture liners had shown few changes in surface roughness for the first three months but highly significant changes were observed in surface hardness at 6 months, whereas, acrylicbased soft denture liners showed minor changes in surface hardness for 1 month, after which they showed significant increase in surface hardness at all intervals (9).

   This study was in support of our study which showed significant increase in hardness and surface roughness in both the acrylic and silicone liners. However, increased hardness and surface roughness was more in the acrylic denture liners than in silicone liners. Brozek et al conducted a study to determine the effect of storage in disinfectants and artificial saliva on a series of commercial soft lining materials for dentures. They found that acrylic materials became less elastic on storage for 28 days whereas the silicone materials showed no changes (12).

   Garcia et al demonstrated that the surface roughness was unaffected when resilient denture liner specimens were immersed in Polident solution. Whereas, in our study it was observed that surface roughness was increased for both acrylic and silicone liner groups when treated with Polident solution (15).

   Denture cleansing affect the properties of the soft lining materials, reducing their elastomeric properties, acrylics was more adversely affected than silicone. These changes are associated with loss of various chemicals, including plasticizers and monomer, from the soft lining materials. These findings were in support of our study too. Tan et al mentioned in study that silicone denture liner when treated with perborate containing denture cleansers showed greater amounts of components could leach out from the liner leading to surface roughness. This study is in favour of our study where the denture cleansers used contained sodium perborate which might have resulted in the increase of surface roughness (13).

   Mese et al mentioned in their study that silicone based resilient liner had significantly lower hardness values than the acrylic based resilient liner. Similar findings were observed where silicone liner group had lower surface hardness values than acrylic liner group (14).

   Garcia et al demonstrated that the surface roughness was unaffected when resilient denture liner specimens were immersed in Polident solution. Whereas, in our study it was observed that surface roughness was increased for both acrylic and silicone liner groups when treated with Polident solution (15).

   The increase in acrylic roughness might be related to the possible loss of soluble components, such as plasticizers, leaving empty spaces. Probably, with time, these empty spaces are responsible for the roughness, increase in size resulting in craters. The surfaces disturbances can also be related to porosity with lining. Air is entrapped during mixing and it appears that some of the cleansers cause the bubbles to increase in size- with some eventually reaching the surface. Such a roughened surface is likely to facilitate colonization by microorganisms (4).

   Quantitative difference in cleanser formulations or pH of the solutions apparently influences the effect of cleanser on the properties of the liners. The use of hot water in combination with a cleanser may cause a more rapid deterioration (7).

   The grade of surface porosity of soft liners varied depending on the immersion time and the combination of denture cleansers and soft liner. A previous study suggested that the oxygenation in strongly alkaline solutions is the damaging factor. They also suggested that peroxide content is one of the possible damaging factors and that other components or the pH of cleansers also affect the surface properties of soft liners (16).

   However a direct comparison of the studies cannot be made because of different tests and different research protocols were used. It is difficult to relate the findings of the present study to other investigations because of the difference of sample size, type of resilient lining materials, duration of experiment, surface preparation and cleanser solutions used. It should be emphasized that the present study has limitations because only two of the many available soft lining materials and denture cleansers were evaluated and the study was performed in laboratory. Test conditions used for in-vitro study do not subject the materials to the aqueous environment, micro-organisms, temperature cycling, abrasion, material thickness and cycling loading. The properties of soft denture liners in the clinical situation still differ from laboratory testing. Further research in a well-controlled clinical trial will be fruitful.

 CONCLUSION

   Within the limitations of the study following conclusions were drawn,

   1) Significant increase in hardness was noted between and within all the acrylic liner groups at all time intervals. Maximum hardness was observed in AP acrylic liner group followed by AE and AW acrylic liner group.

   2) There was a slight increase in hardness of all the silicon liner groups (SP, SE and SW) from day 1 to day 90. Significant difference was seen between the hardness of SP silicon liner group and SE silicon liner group but the hardness of SW silicon liner group remained relatively stable at all time intervals.

   3) Initially the mean surface roughness was same for all the acrylic liner groups but as the time increased, surface roughness also increased, with maximum surface roughness was noted in AP acrylic liner group followed by AE and AW acrylic liner groups.

   4) Effect of denture cleansers on silicon relining material showed slight increase in surface roughness of all the silicon liner groups (SP, SE and SW) from day 1 to day 90 no significant change in surface roughness was noted between and within the groups of the test (SP and SE) and control (AW).

   5) Acrylic liner groups showed higher surface hardness than silicon liner groups at all time intervals. The hardness of acrylic liners and silicon liners increased both with time and also due to effect of denture cleansers.

   6) Maximum surface hardness was noted by cleanser P (Polident) followed by cleanser E (Efferdent Plus) and cleanser W (Water) for both acrylic liner group and silicon liner group.

   7) Maximum surface roughness was noted by cleanser P (Polident) followed by cleanser E (Efferdent Plus) and cleanser W (Water) for both acrylic liner group and silicon liner group.

   This study is entirely laboratory based, however the most appropriate testing environment is the mouth and therefore long-term clinical studies of these materials is required.

 REFERENCES

    1. Garcia RCMR, Leon BLT, Oliveira VMB, Cury AADB. Effect of denture cleanser on weight, surface roughness, and tensile bond strength of two resilient denture liners. J. Prosthet Dent. 2003; 89: 489-494.
    2. El-Hadary A, Drummond JL. Comparative study of water sorption, solubility and tensile bond strength of two soft lining materials. J. Prosthet Dent. 2000; 83: 356-361.
    3. Machado AL, Breeding LC, Puckett AD. Effect of microwave disinfection on the hardness and adhesion of two resilient liner. J. Prosthet Dent. 2005; 94: 183-189.
    4. Wyatt CCL, Harrop TJ, MacEntee MI. A comparsion of physicalcharacterstics of six hard denture reline materials. J. Prosthet Dent. 1986; 55: 343-346.
    5. Sarac D, Sarac YS, Kurt M, Yuzbasioglu E.The effectiveness of denture cleansers on soft denture liners coloured by food colorant solutions. J. Prosthodont. 2007; 16: 185-191.
    6. Malherios-Segundo ADL, Pisani MX, Paranhos HDFO, Souza RFD, et al. Effect of denture cleanser on hardness, roughness and tensile bond strength of denture liners. Braz. J. Oral. Sci. 2008; 7: 1596-1601.
    7. Budtz-Jorgensen E, Odont. Materials and methods for cleansing dentures. J. Prosthet Dent. 1979; 42: 619-623.
    8. Pahuja RK, Garg S, Bansal S, Dang RH. Effect of denture cleansers on surface hardness of resilient denture liners at various time intervals-an in-vitro study. J. Adv. Prosthodont. 2013; 5: 270-277.
    9. Kiat-Amnuay S, Gettleman L, Mekayarajjananonth T, Khan Z, et al.The influence of water storage on durameter hardness of 5 soft denture liners over time. J. Posthodont. 2005; 14: 19-24.
    10. Nikawa H, Iwanaga H, Hamada T, Yuhta S. Effect of denture cleansers on direct soft denture lining materials. J. Prosthet Dent. 1994; 72: 657-662.
    11. Yanikoglu ND, Duymus ZY. Comparative study of water sorption and solubility of soft lining materials in the different solutions. Dent. Mater. 2004; 23: 233-239.
    12. Brozek R, Koczorowski R, Rogalewicz R, Voelkel A, et al. Effect of denture cleansers on chemical & mechanical behavior of selected soft lining materials. Dental materials. 2011; 27: 281-290.
    13. Tan HK, Woo A, Kim S, Lamoureux M, et al. Effect of denture cleansers,surface finish and temperature on Molloplast B resilient liner color, hardness and texture. J. Prosthodont. 2000; 9: 148-155.
    14. Mese A, Guzel KG. Effect of storage duration on the hardness and tensile bond strength of silicone-and acrylic resin-based resilient denture liners to a processed denture base acrylic resin. J. prosthet Dent. 2008; 99: 153-159.
    15. Garcia RCR, Leon BL, Oliveira VM, Cury AADB. Effect of a denture cleanser on weight, surface roughness, and tensile bond strength of two resilient denture liners. J. prosthet Dent. 2003; 89: 489-494.
    16. Harrison A, Basker RM, Smith IS. The compatibility of temporary soft materials with immersion denture cleansers. Int. J. Prosthodont. 1989; 2: 254-258.

ContentFullText

The exquisite patterns on the luxury replica watches dial, the date display window at replica watches six o'clock, and the black sculpted Arabic numerals demonstrate the replica rolex exquisite craftsmanship of rolex watches uk the fine watchmaking style.