Received: August 12, 2008; Accepted: October 21, 2008
International Journal of Biomedical Science 4(4), 310-318, Dec 15, 2008
Original Article


© 2005 Master Publishing Group

A Validated Adsorptive Stripping Voltammetric Determination of Antidiabetic Agent Pioglitazone HCl in Tablets and Biological Fluids

Nawal Ahmad Al-Arfaj, Eman Abdullah Al-Abdulkareem, Fatma Ahmad Aly

Department of Chemistry, College of Science, Women Student-Medical Studies and Science Sections, King Saud University, Saudi Arabia

Corresponding Author: Eman Abdullah Al-Abdulkareem, Department of Chemistry, College of Science, Women Student-Medical Studies and Science Sections, King Saud University, Saudi Arabia. E-mail: ksu_chem@yahoo.com.

Running title: Voltammetric determination of pioglitazone HCl


ABSTRACT
INTRODUCTION
EXPERIMENTAL
RESULTS AND DISCUSSION
VALIDATION OF THE ANALYTICAL
CONCLUSION
ACKNOWLEDGEMENTS
REFERENCES


ABSTRACT

Square-wave adsorptive cathodic stripping voltammetry was used to determine pioglitazone HCl in Britton Robinson buffer of pH5. The adsorptive cathodic peak was observed at −1.5 V vs. Ag/AgCl. The peak response was characterized with respect to pH, supporting electrolyte, frequency, scan increment, pulse-amplitude, accumulation potential and pre-concentration time. Under optimal conditions, the peak current is proportional to the concentration of pioglitazone HCl, and a linear calibration graphs were obtained within the concentration levels of 10-8 and 10-4 M following different accumulation time periods (0-300 s). The obtained results were analyzed and the statistical parameters were calculated. The detection limit is 8.08 × 10-9 M (3.17 ng ml-1) using 300 s pre-concentration time, whereas the quantitative limit is 2.45 × 10-8 M (9.63 ng ml-1). The proposed method was applied to assay the drug in pharmaceutical formulations and biological fluids. The pharmacokinetic parameters of drug in human plasma were estimated as: Cmax=785.8 ng ml-1, tmax=1.5 h, Ke=0.125 h-1 and t1/2 = 8 h which are favorably compared with those reported in literature.

KEY WORDS:     pioglitazone HCl; square-wave; adsorptive stripping voltammetry; biological fluids; actos tablets; pharmacokinetic.

INTRODUCTION

   Pioglitazone hydrochloride, (±)-5-{4-[2-(5-ethyl-2-pyridyl)ethoxy]benzyl}-2,4-thiazolidinedione hydrochloride salt (Fig. 1), is an oral antidiabetic agent that has been shown to affect abnormal glucose and lipid metabolism associated with insulin resistance by enhancing insulin action on peripheral tissues in animal models (1, 2). It is used in the treatment of type-II diabetes (non-insulin-dependent diabetes mellitus, NIDDM also known as adult-onset diabetes) (3, 4).

   Several analytical methods have been reported for the determination of pioglitazone HCl in bulk form, pharmaceuticals and biological fluids. Most of the reported methods are chromatographic, methods and no official methods have been reported for determination of pioglitazone HCl. The reported methods include: high performance liquid chromatography with ultraviolet detection (HPLC-UV) (5-15), high performance liquid chromatography with mass spectroscopy (HPLC/MS) (16), high performance liquid chromatography with tandem mass spectroscopy (HPLC/MS/MS) (17-19), high performance thin layer chromatography (HPTLC) (20, 21), thin layer chromatography (TLC) (22, 23), capillary electrophoresis (CE) (24, 25), and miceller electrokinetic chromatography (MEKC) (26). Other reported methods include a potentiometric method (27) and UV spectrophotometric methods (28, 29). To date no voltammetric procedure has been reported for the assay of pioglitazone HCl.

   Adsorptive stripping voltammetric analysis, especially with the square-wave waveform, is an extremely simple and sensitive technique that can be used for analysis of drugs without the requirement for extraction steps prior to assay. Moreover, square-wave voltammetry is a large-amplitude differential technique in which a waveform composed of a symmetrical square wave is applied to the working electrode (30). The current is sampled twice during each square-wave cycle, once at the end of the forward pulse and once at the end of the reverse pulse. The resulting peak current is proportional to the concentration of the analyte. Excellent sensitivity accrues from the fact that the net current is larger than either the forward or the reverse components current. Coupled with the effective discrimination against the charging current, very low detection limits can be attained. Furthermore, stripping voltammetry is an important technique for trace determination of many inorganic and organic substances (31). The stripping technique has been used successfully for the determination of several drugs (32-38).

   The aim of this work is the quantitative determination of pioglitazone HCl using square-wave adsorptive cathodic stripping voltammetry (SWAdCS). This method is simple, rapid, sensitive and easy to apply in pharmaceutical formulations and in biological samples.


View larger version :
[in a new window]
Figure 1. Structure of pioglitazone HCl.

EXPERIMENTAL

   Apparatus

   An Electrochemical Analyzer (746 VA Trace Analyzer-Metrohm/ Switzerland) was used for SWAdCS voltammetric measurements and Electrochemical Analyzers (797 VA Cumputrace Analyzer-Metrohm/Switzerland) was used for cyclic voltammetry. The electrode assembly of a hanging mercury drop electrode (HMDE) as a working electrode (area=0.05 cm2) for SWAdCS and cyclic voltammetries. Ag/AgCl/KClsat. was the reference electrode and a platinum wire supplied as auxiliary electrode, was used. Stirring of the solution in the electrolysis cell was performed using a complete stirrer comprised as a part of the electrochemical analyzers to provide convective transport during the preconcentration step. The measurements were semi-automated and controlled through the programming capacity of the apparatus. The data were recorded using an external printer attached to the two RS232 interfaces of the 746 VA Trace Analyzer.

   A UV-Vis Spectrophotometer Model (Ultrospec 2100-Pro) was used for a comparative assay of drug in tablets by means of a published spectrophotometric method (28), and for the spectral study of pioglitazone HCl.

   A (Hann pH211-Romania) pH-meter with combined glass and calomel (saturated KCl) electrodes was used for the pH measurements of the supporting electrolytes.

   The de-ionized water used throughout the present study was supplied from (Elgastat Micromeg-England).

   Materials and reagents

   Materials. Pure drug sample of pioglitazone HCl was used (Chargen-Zert.Brand, Germany); Tablets containing pioglitazone HCl (Takeda chemical industries Ltd., Osaka. Japan), were purchased from commercial sources, serum samples were supplied from (United Diagnostics Industry K.S.A.), urine samples were obtained from healthy volunteers. Human plasma samples were provided by (King Khalid University Hospital, Riyadh, SaudiArabia).

   Reagents. The following reagents were used: Britton-Robinson (B-R) buffers (0.08 M) (39), of pH2-11, acetate buffer (39), of pH4.5-5.5, sodium sulphate (Fluka, Switzerland) 0.1M; sodium nitrate (Fluka, Switzerland) 0.1M; sodium perchlorate (Fluka, Switzerland) 0.1M and potassium chloride (Fluka, Switzerland) 0.1M, were prepared using de-ionized water (40), and used as the supporting electrolytes; disodium tetraborate (BDH Ltd., UK) 0.02 M; dichloromethane (BDH Ltd., UK), and methanol (BDH Ltd., UK) were used.

   Procedure

   General analytical procedure. Stock solution (1 × 10-3 M) of pioglitazone HCl was prepared in methanol. This solution was further diluted with methanol to give the appropriate concentrations of working standard solutions. Aliquots of these solutions in the concentration range cited in (Table 1) were transferred into a series of 25 ml volumetric flasks and diluted to the mark with B-R buffer of pH5. Each solution was transferred into the electrolysis cell, and then de-aerated with pure nitrogen. A selected accumulation potential was then applied to the HMDE for a selected preconcentration time period, while the solution was stirred at 400rpm. At the end of the accumulation period, the stirring was stopped and a 5 s rest period was allowed for the solution to become quiescent. Then, the voltammogram was recorded by scanning the potential toward the negative direction using the selected waveform. All the data were obtained at room temperature.

   To study the accuracy and precision of the proposed procedure for the determination of the drug in bulk form, tablets and biological fluids samples; recovery experiments were carried out, by the calibration curve.

   Analysis of tablets. An accurately weighed amount of ten powdered tablets equivalent to 10.0 mg of the drug, was transferred into a 50 ml volumetric flask, then methanol was added to the flask and completed to the mark. The flask with its contents were sonicated for 15 min and filtered. The desired concentrations of the drug were obtained by accurate dilution with methanol and used as working standard solution. An aliquot volume of this solution was transferred into a 25 ml volume calibrated flask then made up to the volume with the supporting electrolyte.

   Analysis of spiked urine and serum. An aliquot of standard methanolic solution of pioglitazone HCl containing 100 μg was added to 1 ml of serum or urine sample in a 15 ml centrifuge tube and mixed for 1 min. 0.2 ml of disodium tetraborate solution (0.02 M) was added and the tube was vortexed for 1 min. 5 ml of dichloromethane was added and the tube was shaken for 10 min. The tube was then centrifuged at 3000 rpm for 10 min at room temperature. The resulting organic layer was removed and the extraction was repeated twice with 5 ml of dichloromethane. The combined extracts were evaporated to dryness at room temperature, and the residue was dissolved in 1 ml of methanol. The solution was transferred into a 10 ml volumetric flask, completed to volume with methanol, and subsequently analyzed according to the recommended in the general analytical procedure. A blank experiment was carried out adopting the above procedure.

   Pharmacokinetic study. The study was performed on one healthy female volunteer. The volunteer fasted overnight before oral administration and for 4 h after dosing. Five ml of venous blood sample was collected 0.5 ;h before dosing to serve as blank, and samples were collected in appropriately labeled lithium-heparin tubes at 0.5, 1, 1.5, 2, 2.5, 3, 5, 7, 14 and 24 h following drug administration. The blood samples were centrifuged immediately at 5000rpm for 15 min, and plasma was rapidly collected and stored at −20°C until assayed. Each plasma sample was assayed by using the square-wave adsorptive cathodic stripping voltammetric procedure, and the values provide the plasma concentration at the time period of collection of the blood sample. The pharmacokinetic parameters were evaluated from the plasma concentration-time profile.

   Spectral study. A preliminary study for the spectra (Absorbance - wavelength λ) of 5 × 10-5 M pioglitazone HCl in B-R buffers pH2-11 was carried out. The spectra exhibited two bands at 221 and 270nm within the entire pH range. The maximum absorbance of the first peak increased slightly while that of the second peak decreased practically with the same rate upon the increase of pH. From the S and Z shaped absorbance - pH curves for the first (λ=221nm) and second (λ=270nm) bands, respectively, the pKa of pioglitazone HCl was estimated and found to equal 5.8 and 6.1, respectively, with a mean pKa value of 5.95.

RESULTS AND DISCUSSION

   Effect of type and pH of the supporting electrolyte

   The effect of pH was studied on the SWAdCS voltammetric response for 5 × 10-5M pioglitazone HCl and was examined in B-R buffers over the pH range 2-11 with pre-concentration (tacc=30s). The voltammograms exhibited a single well-defined four-electron irreversible cathodic peak over the pH range (4.5-8). This peak may be attributed to the hydrogenation of two C=O double bonds via the consumption of four-electrons per drug molecule. The peak potential shifted to more negative values upon pH increase of the medium denoting that protons are involved in the electrode reaction process and that the proton-transfer reaction preceedes the electrode process properly (41-43). As shown in Fig. 2 the peak current intensities (ip) recorded at different pH values following pre-concentration for 30s. A much higher peak current intensity was achieved in B-R buffers of pH5. Other supporting electrolytes such as acetate buffer pH(4.5-5.5), sodium sulfate, sodium nitrate, sodium perchlorate and potassium chloride were also tested but the peak current intensity was less developed compared to that obtained in B-R buffer of pH5. Therefore, B-R buffer of pH5 was used as a supporting electrolyte in the rest of the present work. Fig. 3 shows SWAdCS voltammetry of 5 × 10-5M pioglitazone HCl in B-R buffer of pH5.

   Optimization of the proposed analytical procedure

   The SWAdCS voltammetric response markedly depends on the parameters of the excitement signal. In order to reach a maximum developed SWAdCS voltammetric peak current, the optimum instrumental conditions (frequency f, scan increment ΔEs and pulse amplitude Esw) were studied for 5 × 10-5M pioglitazone HCl in B-R buffer of pH5, following preconcentration for 30s. At a scan increment of 10mV and a pulse-amplitude of 25mV, the peak current intensity increased linearly over the frequency range (40-120)Hz, following the relationship: ip (μΑ)=0.93 f (Hz) + 0.08 (r=0.996 and n=6). At a frequency of 120Hz and a pulse-amplitude of 25mV, the peak current intensity increased linearly with the scan increment up to 10mV, following the relationship: ip (μΑ)=1.14ΔEs (mV) + 0.96 (r=0.997 and n=4). Also, at f=120Hz and ΔEs=10mV, the peak current increased linearly with the increase of the pulse-amplitude from 15 to 50mV, however the sharper peak was obtained at 25mV. Therefore, the optimal instrumental operational conditions of the proposed square-wave procedure can be concluded as: frequency f=120Hz, scan increment ΔEs=10mV and pulse amplitude Esw=25mV. On the other side, the effect of varying accumulation potential (Eacc) from −0.8 to −1.7V on the peak current intensity of the SWAdCS voltammogram of 5 × 10-5M pioglitazone HCl in B-R buffer of pH5, following preconcentration for 30s was evaluated in (Fig. 4). A maximum developed peak current was achieved over the potential range of −1.3 to −1.6V. The observed gradual decrease in peak current intensity may be attributed to the consequence of desorption of the drug at higher or lower potential values. Hence, an accumulation potential of −1.5V (versus Ag/AgCl/KClsat.) was chosen throughout the present study.

   Effect of accumulation time

   The SWAdCS voltammogram of 1 × 10-6, 3 × 10-6, 5 × 10-6, 7 × 10-6 and 9 × 10-6 M pioglitazone HCl were recorded under the optimal operational conditions at increased accumulation time. Fig. 5 shows the effect of different pre-concentration time for the above concentrations of pioglitazone HCl in the presence of B-R buffer of pH5, and accumulation potential of −1.5 V. Straight lines with slopes 0.05 and 0.06 μA s-1 were obtained for 1 × 10-6 and 3 × 10-6 M pioglitazone HCl, respectively where the straight lines break at tacc=150 s. However at higher concentrations, the straight lines break at tacc=100 sfor 5 × 10-6 M pioglitazone HCl and at tacc=60 s for 7 × 10-6 and 9 × 10-6 M pioglitazone HCl, respectively. The breaks at certain stirring accumulation times mean that surface coverage was attained. The slope of the straight lines are 0.07 , 0.12 and 0.14 μA s-1 for 5 × 10-6, 7 × 10-6 and 9 × 10-6 M pioglitazone HCl, respectively and the increase in the slope is due to the increase in the concentration. The collected data are summarized in Table 2.

   Effect of concentration

   The SWAdCS voltammetry of series of solutions containing different concentrations of pioglitazone HCl in the range cited in (Table 1) were recorded under optimal operational conditions, f=120Hz, scan increment ΔEs=10mV, pulse-amplitude Esw=25mV and accumulation potential Eacc=-1.5V at increased accumulation time. The peak current intensity showed a linear relationship with the accumulation time up to 100, 150 and 300s for the concentration levels of 7 × 10-7, 2 × 10-7 and 4 × 10-8M of pioglitazone HCl, respectively. This means that the optimal accumulation time period should be chosen according to the concentration level of pioglitazone HCl in the investigated sample (i.e. the higher the concentration, the shorter the accumulation time is). Table 1 illustrates the characteristics of the calibration curves of SWAdCS voltammetric determination of pioglitazone HCl.

   Adsorptive character of the drug

   Fig. 6 shows the cyclic voltammograms of 5 × 10-4M pioglitazone HCl in B-R buffer of pH5, scan rate v=100 mVs-1 recorded without pre-concentration, tacc=0s (dashed curve), following pre-concentration for 30s (curve 1) and then its repetitive cycle at the same mercury drop (curve 2). A more developed peak current was achieved after pre-concentration of the drug onto the electrode surface, whereas the second cycle at the same mercury drop exhibited lower peak current intensity which may be due to the desorption of drug species out of the mercury electrode surface. This behavior indicated the interfacial adsorptive character of the drug onto the mercury electrode surface.

   Analytical applications

   Analysis of tablets. The developed SWAdCS voltammetric procedure was applied (tacc= 60s) for the determination of pioglitazone HCl in its pharmaceutical formulations (Actos tablets 15 and 30mg pioglitazone HCl) without the necessity for any extraction steps. Recoveries of pioglitazone HCl in both dosage forms, based on the average of three replicate measurements, are illustrated in Table 3. The results were statistically compared with those obtained by the published spectrophotometric method (28). Values of Student’s t-value, Variance ratio, are also included. Since the calculated Variance ratio did not exceed the theoretical one, there was no significant difference between the proposed and puplished methods with respect to accuracy and precision (44).

   Analysis of spiked urine and serum. The high sensitivity attained by the proposed method allows the determination of pioglitazone HCl in biological fluids. Pioglitazone HCl is rapidly absorbed after oral administration. Peak plasma concentrations are obtained within 2 hours and bioavailability exceeds 80%. Pioglitazone HCl is more than 99% bound to plasma proteins. It is extensively metabolised by cytochrome P450 isoenzymes CYP3A4 and CYP2C9 to both active and inactive metabolites. It is excreted in urine and faeces and has a plasma half-life of up to 7 hours. The active metabolites have a half-life of up to 24 hours (45).

As a consequence, the proposed method appears to be convenient for the therapeutic drug monitoring in urine and serum. In addition, the SWAdCS voltammetry, requiring smaller volumes of samples, may be valuable for routine drug screening of patients under treatment. The extraction procedure for biological fluids was performed by using dichloromethane, as reported by Kolte et.al (46). Table 4 and 5 show the performance data and the results for determination of pioglitazone HCl in urine and serum, respectively. The results show that pioglitazone HCl can be determined in spiked serum and urine over the concentration range 6 × 10-8 - 4 × 10-7M.

   Pharmacokinetic application. In a trial to prove the utility of the proposed SWAdCS voltammetric procedure in clinical analysis, the procedure was applied to determination of the pharmacokinetic parameters of pioglitazone HCl in blood samples of one healthy female volunteer following an oral administration of a single dose of Actos tablets (30 mg). Fig. 7 shows the plasma concentrations versus time profile. The obtained pharmacokinetic parameters are shown in Table 6. The obtained results were favorably compared with those obtained by reported methods (47-50), which can be considered as an indication for the reliability of the proposed procedure for assay of pioglitazone HCl in real human plasma samples without interference from its metabolites.


View larger version :
[in a new window]
Figure 2. Influence of pH (B-R buffers) on the SWAdCS voltammetric peak current (ip) of 5 × 10-5M pioglitazone HCl; frequency f=120Hz, scan increment ΔEs=10mV and pulse-amplitude Esw=25mV, with tacc=30s at −1.5V.

View larger version :
[in a new window]
Figure 3. SWAdCS voltammetry of (a) 5 × 10-5M pioglitazone HCl in B-R buffer of pH5 (-), (b) B-R buffer of pH5 (---); frequency f=120Hz, scan increment ΔEs=10mV, pulse-amplitude Esw=25mV and tacc=30s at Eacc = −1.5V.

View larger version :
[in a new window]
Figure 4. Effect of accumulation potential (Eacc) on the SWAdCS voltammetric peak current (ip) of 5 × 10-5M pioglitazone HCl in B-R buffer of pH5; frequency f=120Hz, scan increment ΔEs=10mV and pulse-amplitude Esw=25mV, following preconcentration for tacc= 30s.

View larger version :
[in a new window]
Figure 5. Peak current vs. accumulation time in the presence of B-R buffer of pH5, accumulation potential −1.5 V for: (a) 1 × 10-6 M; (b) 3 × 10-6 M; (c) 5 × 10-6 M; (d) 7 × 10-6 M; (e) 9 × 10-6 M of pioglitazone HCl.

View larger version :
[in a new window]
Figure 6. Cyclic voltammograms of 5 × 10-4M pioglitazone HCl in B-R buffer of pH5; without preconcentration (tacc=0s) (dashed curve), following preconcentration for 30s (curve 1) and its repetitive cycle at the same mercury drop (curve 2), Scan rate ν=100mVs-1 and Eacc =-1.5V.

View larger version :
[in a new window]
Figure 7. Plasma concentration-time profile for healthy female volunteer after oral administration of 30 mg pioglitazone HCl tablet.

VALIDATION OF THE ANALYTICAL

   Validation of the procedure for the quantitative assay of pioglitazone HCl was examined via evaluation of the limit of detection (LOD), limit of quantitation (LOQ), repeatability, recovery and robustness. Calibration curves within the concentration levels of 10-8 and 10-4M pioglitazone HCl were attempted following different accumulation time periods (0-300s). The regression equations associated with the calibration plots exhibited good linearity (Table 1) that supported the validation of the proposed procedure for quantitation of pioglitazone HCl. The limits of detection (LOD) and quantitation (LOQ) were calculated using the relation k(δ a)/b (51), where k=3.3 for LOD and 10 for LOQ, (δ a) is the standard deviation of the intercept and b is the slope of the calibration curve. Both LOD and LOQ values are shown in Table 1.

   The repeatability of the results obtained by means of the proposed SWAdCS voltammetric procedure was examined by performing 15 replicate measurements for 5 × 10-5M pioglitazone HCl following pre-concentration for 30s. A mean recovery of 99.3 ± 0.77 (n=15) and RSD%<2 were achieved, that indicated high precision of the proposed procedure for assay of the drug.

   The selectivity of the optimized procedure for the assay of pioglitazone HCl was examined in the presence of some common excipients (usually present in formulations, e.g. starch, gelatin, lactose, talc and magnesium stearate) and so there is no significant interference from excipients. Accordingly, the proposed procedure can be considered selective.

   The robustness (51) of results of a procedure is the ability to remain unaffected by small changes in its operational parameters such as pH and accumulation potential. In the present work, this was examined by studying the effect of small variation of pH(4.8-5.2) and accumulation potential (Eacc=−1.4 to −1.6V). As shown in Table 7, the recovery values were not significantly affected by these variations and consequently the optimized procedure was reliable for assay of pioglitazone HCl and it could be considered robust (51).


View this table:
[in a new window]
Table 1. Characteristics of the calibration curves of SWAdCS voltammetric determination of pioglitazone HCl


View this table:
[in a new window]
Table 2. Characteristic of current-time curves established using different concentrations of pioglitazone HCl in B-R buffer of pH5.


View this table:
[in a new window]
Table 3. Analysis of pioglitazone HCl in its tablets by the proposed SWAdCS voltammetry (in B-R buffer of pH 5 and tacc = 60 s)and the published spectrophotometric methods (28)


View this table:
[in a new window]
Table 4. Performance data of piogletazone HCl by the proposed SWAdCS voltammetry (in B-R buffer of pH5 and tacc =300 s) in serum and urine


View this table:
[in a new window]
Table 5. Determination of pioglitazone HCl in spiked serum and urine by the proposed SWAdCS voltammetry, tacc=300 s


View this table:
[in a new window]
Table 6. Estimated pharmacokinetic parameters of pioglitazone HCl in plasma of one healthy female volunteer following an oral administration of a single dose of 30mg Actos tablet


View this table:
[in a new window]
Table 7. Influence of small variations of some of the operationl conditions of the proposed procedure on the % Found of 5 × 10-5 M pioglitazone HCl; frequency=120 Hz, scan increment=10 mV and pulse-amplitude=25 mV

CONCLUSION

   A new highly sensitive, rapid, selective and reproducible SWAdCS voltammetric procedure for the determination of pioglitazone HCl drug in bulk form, pharmaceutical formulations and biological fluids is described. The proposed procedure showed clear advantages, e.g. short period of real time of drug analysis, and a very simple extraction procedure was used for urine and serum samples. Moreover, the proposed method could be applied in clinical laboratories and pharmacokinetic studies because of its very low limits of detection and quantitation.

ACKNOWLEDGEMENTS

The authors wish to deep thank Dr.Huda A. Al-Abdulkareem for her kindness of providing the great facilities for collection and treatments of plasma samples required for the pharmacokinetic study. Also, the authors thank the Women Students Medical Studies & Science Sections' Research Centre of Deanship of Academic Research in King Saud University for supporting this work.

REFERENCES

    1. T. Sohda, K. Mizuno, Y. Momose , H. Ikeda, T. Fujita and K. Meguro, J. Med. Chem. 1992; 35: 2617-2626.
    2. M. Kobayashi, M. Iwanishi, K. Egawa and Y. Shigeta, Diabetes. 1992; 41:476-483.
    3. J.Waugh, G. M. Keating, G.L. Plosker, S. Easthope and D.M. Robinson, Drugs. 2006; 66:85-109.
    4. J. Chilcott, P. Tappenden, M. Lloyd and J.P. Wight, Clin. Ther. 2001; 23:1792-1823.
    5. C. Giaginis, S.Theocharis and A. Tsantili-Kakoulidou, J. Chromatogr. B. 2007; 857:181-187.
    6. P. Sripalakit, P. Neamhom and A. Saraphanchotiwitthaya, J. Chromatogr. B. 2006; 843:164-169.
    7. S. Wittayalertpanya, S. Chompootaweep, N. Thaworn, J. Med. Assoc. Thai. 2006; 89:2116-2122.
    8. P. Venkatesh, T. Harisudhan, H. Choudhury, R. Mullangi, N. R. Srinivas, Biomed Chromatogr. 2006; 20 :1043-1048.
    9. D. B. Wanjari, N. J. Gaikwad, I. J. P. S. 2005; 67:256-258.
    10. R. T. Sane, S. N. Menon, S. Inamdar, M. Mote, G. Gundi, Chromatographia. 2004; 59:451-453.
    11. B. L. Kolte, B. B. Raut, A. A. Deo, M. A. Bagool, D. B. Shinde, J.Chromatogr.Sci. 2004; 42: 27-31.
    12. W. Z. Zhong and D. B. Laking, J. Chromatogr. Biomed. Appl. 1989; 490:377-385.
    13. W. Z. Zhong and M.G. Williams, J. Pharm. Biomed. Anal. 1996; 14:465-473.
    14. K. Yamashita, H. Murakami, T. Okuda, and M. Motohashi, J. Chromatogr. B. 1996; 677:141-146.
    15. J. D. Dai, D. J. Jin and Y. L. Liu, Yaowu. Fenxi, Zazhi. 2001; 21:36-39.
    16. Y. H. Xue, K.C. Turner, J.B. Meeker, J. Pursley, M. Arnold, and S. Unger, J. Chromatogr. B. 2003; 795:215-226.
    17. M. Wang, and I. R. Miksa, J. Chromatogr. B. 2007; 856:318-327.
    18. Z. J. Lin, W. Ji, D. Desai-Krieger, and L. Shum, J. Pharm. Biomed. Anal. 2003; 33:101-108.
    19. E. N. M. Ho, K. C. H. Yiu, T. S. M. Wan, B. D. Stewartand and K. L. Watkins, J. Chromatogr. B. 2004; 811:65-73.
    20. A. Gumieniczek, H. Hopkala, A. Berecka, J.Liq.Chromatogr.Relat.Technol. 2004; 27:2057-2070.
    21. R. T. S. Menon, S. Inamdar, M. Mote, A. Menezes, J.Planar.Chromatogr.Mod.TLC. 2004; 17:154-156.
    22. A. Gumieniczek, H. Hopkala, A. Berecka, D. Kowalczuk, J.Planar.Chromatogr.Mod.TLC. 2003; 16 :271-275.
    23. B. Ravi, G. Deepak, J. Aishwarya, J.Planar.Chromatogr.Mod.TLC. 2006; 19:288-296.
    24. B. Jamali, G. C. Theill and L. L. Sorensen, J. Chromatogr.A. 2004; 1049:183-187.
    25. B. Jamali, I. Bjornsdottir, O. Nordfang and S. H. Hansen, J. Pharm. Biomed. Anal. 2008; 46:82-87.
    26. T. Radhakrishna, D. Sreenivas, and G. O. Reddy, J. Pharm. Biomed. Anal. 2002; 29:593-607.
    27. G. A. E. Mostafa and A. Al-Majed, J. Pharm. Biomed. Anal. 2008, in press.
    28. D. G. Sankar, J. M. R. Kumar and M. V. V. N. Reddy, Asian J. Chem. 2004; 16:537-539.
    29. D. G. Sankar, J. M. R. Kumar and M.V.V.N. Reddy, Asian J. Chem. 2004; 16:245-251.
    30. J.G. Osteryoung and R.A. Osteryoung, Anal. Chem. 1985; 57:101A-110A.
    31. J. Wang, In: Stripping Analysis, VCH Publishers, Inc. 1985:59.
    32. O. A. Farghaly, H. M. Abd El-Wadood and M. A. Ghandour, J. Pharm. Biomed. Anal. 1999; 21: 233-240.
    33. A. M. M. Ali, Anal. Lett. 1993; 26:1635-1647.
    34. A. M. M. Ali, K. M. Emara and M. Khodari, Analyst. 1994; 119:1071-1074.
    35. M. A. Ghandour and A. M. M. Ali, Anal. Lett. 1991; 24:2171-2186.
    36. J. Wang and J.Fresenius, Anal. Chem. 1990; 337:508-511.
    37. M. A. Ghandour, E. Aboul Kasim, A. M. M. Ali, M. T. El-Haty and M. M. Ahmed, J. Pharm. Biomed. Anal. 2001; 25:443- 451.
    38. M. M. Ghoneim, M. A. El Ries, E. Hammam, and A. M. Beltagi, Talanta. 2004; 64:703-710.
    39. J. Heyrovsky, P. Zuman, In: Practical Polarography, Academic press, New York. 1968:163,179.
    40. J. Lurie, Hand Book of Analytical Chemistry, Mir Publisher. 1975:253-261.
    41. P. Zuman, In: The Elucidation of Organic Electrode Processes, Academic Press. New York. 1969:21.
    42. M. M. Ghoneim, M. M. Mabrouk, and A. Tawfik, J. Pharm. Biomed. Anal. 2002; 30:1311-1318.
    43. I. S. El-Hallag, G. B. El-Hefnawy, Y. I. Moharram, and E. M. Ghoneim, Can. J. Chem. 2000; 78 :1170-1177.
    44. R. Caulcutt and R. Boddy, Statistics for Analytical Chemists, Chapman and Hall, London. 1983.
    45. S. C. Sweetman, Martindale, The complete drug reference. 33 ed. London, Chicago: Pharmaceutical Press. 2002:333.
    46. B. L. Kolte, B. B. Raut, A. A. Deo, M. A. Bagool and D. B. Shinde, J. Chromatogr.B. 2003; 788:37- 44.
    47. D. A. Eckland, and M. Danhof, Exp. Clin. Endocrinol. Diabetes. 2000; 108:234-242.
    48. M. Hanefeld, Int. J. Clin. Pract. Suppl. 2001; 121:19-25.
    49. M. L. Christensen, B. Meibohm, E. V. Capparelli, P. Velasquez-Mieyer, G.A. Burghen and W. V. Tamborlane, J. Clin. Pharmacol. 2005; 45:1137-1144.
    50. H. Wong, Y. Ozalp, A. Lainesse, and R. S. Alpan, Arzneimittelforschung. 2004; 54:618-624.
    51. The United States Pharmacopoeia, The National Formularly, USP 26, Rockville, MD, 2003:2442.
ContentFullText

The exquisite patterns on the luxury replica watches dial, the date display window at replica watches six o'clock, and the black sculpted Arabic numerals demonstrate the replica rolex exquisite craftsmanship of rolex watches uk the fine watchmaking style.